AbiTause Collection

Abitause

3 Lead Holter ECG Monitor Machine Recorder Analyzer Sync Software TLC5007

$550.00

  • 3 Lead Holter ECG Monitor Machine
  • Holter ECG Recorder: Monitors heart activity over an extended period.
  • Three-Lead Configuration: Provides detailed cardiac data.
  • Precise Analysis: Detects irregularities for accurate diagnosis.
  • Sync Software Included: Simplifies data retrieval and analysis.
Clear
Compare
SKU: CJZN1713498 Category:

Introduction

Dynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.

Function

1)The recorder can real-time store ECG data for 24-hour.

2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.

3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.

4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.

5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.

6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.

7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.

8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.

9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.

10)One-key print, convenient and fast to print the reports.

11)Perfect case management function.

12)The risk of sleep breath pause can be predicted by the unique “Sleep breath pause syndrome”analysis function.

13)The death risk in patients with myocardial infarction can be predicted by the “HRT” analysis function.

14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death

Performance

Lead: 3-lead

Record time: ≥24-hour

Power supply: two “AA” alkaline batteries

Interface: USB2.0

Sampling accuracy: 24bit

Sampling frequency: 250Hz

Dynamic range: 10mV

Input impedance: ≥10MΩ

CMR: ≥60dB

Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%

Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.

System noise: ≤50µVp-p

Multichannel crosstalk: ≤0.2mV

Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.

Minimum measure signal: 50 µV

With the function in the presence of pacemaker pulses

Timing accuracy: the overall error during 24h shall not exceed 30s.

Accessories

Lead cable (1 set)

ECG electrode (1 bag)

USB cable(1)

Bag(1)

User manual(1)

Physical characteristic

Dimension: 111mm(L) × 61mm(W) × 25mm(H)

Weight: about 105g

Additional information

Weight 1.00 kg
Dimensions 210 × 200 × 110 cm
Model

TLC5007

Reviews

There are no reviews yet.

Be the first to review “3 Lead Holter ECG Monitor Machine Recorder Analyzer Sync Software TLC5007”

Your email address will not be published. Required fields are marked *