AbiTause Collection

Abitause

CA10S Handheld Veterinary Sidestream Capnograph VET CO2 Patient Monitor ETCO2

$600.00

  • CA10S Handheld Veterinary Sidestream Capnograph
  • VET CO2 Patient Monitor: Specifically designed for animal healthcare.
  • Sidestream Capnography: Provides continuous and real-time ETCO2 monitoring.
  • Essential for Veterinary Care: Helps assess patient respiratory and metabolic status.
  • Handheld Portability: Easily transport and use in various clinical settings.
Clear
Compare
SKU: CJZN1740314 Category:

Introduction

The device adopts sidestream method to measure the animal’s parameter related to EtCO2 and AwRR. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow and indirectly reflect the alveolar ventilation. It can also be paired with blood oxygen probe to detect animal blood oxygen and pulse.

It is applicable for use in pre-hospital emergency , emergency department, ICU, operating room of pet hospitals at all levels.

Features

1)End-tidal CO2 measurement function;

2)Respiration rate measurement function;

3)SpO2 measurement function;

4)Pulse rate measurement function;

5)Optional three units;

6)With audible and visual alarm and silencing functions, the alarm limit can be set;

7)Over-limit alarm function for EtCO2, Respiration rate;

8)Low battery alarm function;

9)With the prompt function of “Checking Filterline”;

10)User can calibrate zero by themselves.

11)With atmospheric pressure and temperature compensation functions

12)Rechargeable lithium battery, up to 8-hour user time;

Performance

End-tidal CO2 measurement:

1)Measurement range: 0 ~150mmHg

2)Resolution: 1mmHg

3)Accuracy: 0~40 mmHg:±2 mmHg

41~70 mmHg:±5% of readings

71~100 mmHg:±8% of readings

101~150 mmHg:±10% of readings

Respiration rate measurement:

1)Measurement range: 2rpm~120rpm

2)Resolution: 1rpm

3)Accuracy: ±1rpm

SpO2 measurement:

1)Measurement range: 30%~100%

2)Resolution: 1%

3)Accuracy: 70 % ~ 100 %:±2 %;

30 % ~ 69 %:undefinition.

Pulse rate measurement:

1)Measurement range: 25 bpm ~ 250 bpm;

2)Resolution: 1bpm;

3)Accuracy: ±2 bpm or ±2%,whichever is greater.

Safety characteristic:

1)Device type: internally powered equipment

2)Degree of protection against electric shock: type BF applied part

3)Degree of protection against ingress of liquid: IPX1

Other parameters:

1)Preheat time: 2min;

2)Response time: < 3s;

3)Alarm sound pressure level: 50 dB;

4)Battery life time: 8hours;

5)Gas sampling rate: 60 ml/min ~ 100 ml/min.

Accessories

User Manual

Sampling tube(Cannula tube with filter cotton)

USB cable

Physical Characteristic

Dimension: 159*72*31 mm

Weight: 270 g

Working environment

Temperature: 5℃~40℃

Relative humidity: 30%~ 75%, no condensation

Atmospheric pressure: 700hPa~1060hPa

Power supply: DC 3.7V (rechargeable lithium batteries)

Input power: ≤1.5VA

Additional information

Weight 0.50 kg
Dimensions 250 × 130 × 60 cm
Model

CA10SVET

Reviews

There are no reviews yet.

Be the first to review “CA10S Handheld Veterinary Sidestream Capnograph VET CO2 Patient Monitor ETCO2”

Your email address will not be published. Required fields are marked *